Vcenter6.5扩容存储后无法创建虚机处理方法
Error: "PBM error occurred during PreCreateCheckCallback: Connection refused" while creating protection group
- 占位创建步骤创建保护组失败:
- 您会看到以下错误:
PBM error occurred during PreCreateCheckCallback: Connection refused
- 在 Dr.log 文件中,您会看到类似以下内容的条目:
2018-04-03T09:41:43.453-04:00 verbose vmware-dr[02344] [Originator@6876 sub=ProductionVmManagerImpl opID=5fe36d70] [UpdatePlaceholderVmInfo] Updating PlaceholderVmInfo for protected VM 'protected-vm-24455':
--> (dr.replication.ProtectedVm.PlaceholderVmInfo) {
--> vm = <unset>,
--> folder = <unset>,
--> computeResource = <unset>,
--> resourcePool = <unset>,
--> host = <unset>,
--> datacenter = <unset>,
--> placeholderCreationFault = (vmodl.fault.SystemError) {
--> faultCause = (vmodl.MethodFault) null,
--> faultMessage = <unset>,
--> reason = " PBM error occurred during PreCreateCheckCallback: Connection refused"
--> msg = "A general system error occurred: PBM error occurred during PreCreateCheckCallback: Connection refused"
--> },
--> repairNeeded = true
--> }service-control --status vmware-vpx-workflow
- 在 DR vCenter 上的 vpxd.log 文件中,会看到类似以下的条目:
2018-04-03T09:41:44.034-04:00 info vpxd[7F39FF366700] [Originator@6876 sub=vpxLro opID=251adf5f:cd52-39] [VpxLRO] -- BEGIN task-2862 -- group-v41 -- vim.Folder.createVm -- 52ba72f1-a57c-4a3c-a60f-d30583a1d10f(52d8bf33-59ad-138f-fd78-2d98
f69e3ee9)
2018-04-03T09:41:44.036-04:00 info vpxd[7F39FF366700] [Originator@6876 sub=vpxLro opID=251adf5f:cd52-39-01] [VpxLRO] -- BEGIN lro-245274 -- -- VmprovWorkflow --
2018-04-03T09:41:44.036-04:00 info vpxd[7F39FF366700] [Originator@6876 sub=VmProv opID=251adf5f:cd52-39-01] Execute local action vpx.vmprov.InvokePrechecks (5%)
2018-04-03T09:41:44.036-04:00 info vpxd[7F39FF366700] [Originator@6876 sub=VmProv opID=251adf5f:cd52-39-01] Invoking callback type 0 on CryptoManager
2018-04-03T09:41:44.036-04:00 info vpxd[7F39FF366700] [Originator@6876 sub=VmProv opID=251adf5f:cd52-39-01] Invoking callback type 0 on DVS
2018-04-03T09:41:44.036-04:00 info vpxd[7F39FF366700] [Originator@6876 sub=VmProv opID=251adf5f:cd52-39-01] Invoking callback type 0 on EventEmitter
2018-04-03T09:41:44.036-04:00 info vpxd[7F39FF366700] [Originator@6876 sub=VmProv opID=251adf5f:cd52-39-01] Invoking callback type 0 on FT
2018-04-03T09:41:44.036-04:00 info vpxd[7F39FF366700] [Originator@6876 sub=VmProv opID=251adf5f:cd52-39-01] Invoking callback type 0 on InvtId
2018-04-03T09:41:44.036-04:00 info vpxd[7F39FF366700] [Originator@6876 sub=VmProv opID=251adf5f:cd52-39-01] Invoking callback type 0 on Iofilter
2018-04-03T09:41:44.036-04:00 info vpxd[7F39FF366700] [Originator@6876 sub=VmProv opID=251adf5f:cd52-39-01] Invoking callback type 0 on PbmCallBack
2018-04-03T09:41:44.036-04:00 info vpxd[7F39FF366700] [Originator@6876 sub=pbm opID=251adf5f:cd52-39-01] PBMCallback: PreProvisionProcess: Calling pbm PreProvisionProcess
2018-04-03T09:41:44.036-04:00 warning vpxd[7F39FDC38700] [Originator@6876 sub=Default] Failed to connect socket; <io_obj p:0x00007f3a501ee580, h:83, <TCP '0.0.0.0:0'>, <TCP '127.0.0.1:8190'>>, e: system:111(Connection refused)
2018-04-03T09:41:44.037-04:00 error vpxd[7F39FF366700] [Originator@6876 sub=pbm opID=251adf5f:cd52-39-01] PBMCallback: HandleInternalFaultMessage: PBM error occurred during PreCreateCheckCallback: Connection refused
2018-04-03T09:41:44.037-04:00 error vpxd[7F39FF366700] [Originator@6876 sub=VmProv opID=251adf5f:cd52-39-01] Get exception while executing action vpx.vmprov.InvokePrechecks: N5Vmomi5Fault11SystemError9ExceptionE(vmodl.fault.SystemError)
--> [context]zKq7AVECAAAAAEklWwAgdnB4ZAAAeF4rbGlidm1hY29yZS5zbwAAEBcbAMppGAEu0VR2cHhkAAFD01QB3B6rAXauqgGhxcwBX8/MATHfzwEJmNABMtHNAbjzzQEF+c0BS59zAcCUcwFPuHMBon9zAT16yQFGe8kBeKZ4gkNdBgFsaWJ2aW0tdHlwZXMuc28AAfymdAFLn3MBwJRzAU+4cwGAC3QAR6wjAC6vIwA3tysDVHQAbGlicHRocmVhZC5zby4wAAQdjA5saWJjLnNvLjYA[/context]
2018-04-03T09:41:44.040-04:00 info vpxd[7F39FF366700] [Originator@6876 sub=VmProv opID=251adf5f:cd52-39-01] Workflow context:
--> (vpx.vmprov.CreateContext) {
--> cbData = (vmodl.KeyAnyValue) [
--> (vmodl.KeyAnyValue) {
--> key = "pbmPreCheckSkipped",
--> value = false
--> }
2018-04-03T09:41:44.043-04:00 error vpxd[7F39FF366700] [Originator@6876 sub=vpxLro opID=251adf5f:cd52-39-01] [VpxLRO] Unexpected Exception: N5Vmomi5Fault11SystemError9ExceptionE(vmodl.fault.SystemError)
--> [context]zKq7AVECAAAAAEklWwAgdnB4ZAAAeF4rbGlidm1hY29yZS5zbwAAEBcbAMppGAEu0VR2cHhkAAFD01QB3B6rAXauqgGhxcwBX8/MATHfzwEJmNABMtHNAbjzzQEF+c0BS59zAcCUcwFPuHMBon9zAT16yQFGe8kBeKZ4gkNdBgFsaWJ2aW0tdHlwZXMuc28AAfymdAFLn3MBwJRzAU+4cwGAC3QAR6wjAC6vIwA3tysDVHQAbGlicHRocmVhZC5zby4wAAQdjA5saWJjLnNvLjYA[/context]
2018-04-03T09:41:44.046-04:00 info vpxd[7F39FF366700] [Originator@6876 sub=vpxLro opID=251adf5f:cd52-39-01] [VpxLRO] -- FINISH lro-245274
2018-04-03T09:41:44.046-04:00 info vpxd[7F39FF366700] [Originator@6876 sub=Default opID=251adf5f:cd52-39-01] [VpxLRO] -- ERROR lro-245274 -- -- VmprovWorkflow: vmodl.fault.SystemError:
--> Result:
--> (vmodl.fault.SystemError) {
--> faultCause = (vmodl.MethodFault) null,
--> faultMessage = <unset>,
--> reason = " PBM error occurred during PreCreateCheckCallback: Connection refused"
--> msg = ""
--> }
--> Args:
注意:上述日志摘录仅为示例。日期、时间和环境变量可能会因环境而有所不同。
1.扩容LUN空间
2.创建虚机报如下错误
官方KB: VMware Knowledge Base
官方解决KB:VMware Knowledge Base
3.如果不清楚重启服务的情况下可以重启Vcenter服务(问题修复)
重启Vcenter命令,通过ssh登录Vcenter
输入root
输入shell
输入service-control --stop --all
输入service-control --start --all